Hologic has partnered with multiple sites across the world to demonstrate the strong clinical benefits of its SuperSonic® MACH™ ultrasound systems applicated to various organs.

Rollover the body area to learn more.

Hologic has partnered with multiple sites across the world to demonstrate the strong clinical benefits of its SuperSonic® MACH™ ultrasound systems applicated to various organs.

Click the body area title to learn more.

Dynamic Assessment of the Musculo-Skeletal Systems

ShearWave™ PLUS Elastography imaging with its unique and even higher ability to analyze tissue stiffness (up to 1,200 kPa or 20 m/s), and in real time, is an asset for tendinopathy assessment and muscle disorders quantification. By adding innovative imaging modes, such as Angio PLUS imaging and Needle PLUS imaging, ultrasound exams benefit from complementary diagnostic information.

The utility of ShearWave™ Elastography imaging for Musculo-Skeletal systems has been demonstrated in more than 200 publications1 to:

  • Explore both inflammatory and mechanical disorders, such as tendinopathies
  • Screen and assess musculoskeletal injuries
  • Turn subjective muscular examination into quantifiable objective assessment
  • Obtain precise characterization of the musculoskeletal unit for a more confident diagnosis.
  • Monitor Treatment
  1. PEER-REVIEWED ARTICLES SHEARWAVE™ ELASTOGRAPHY FOR MUSCULO- SKELETAL SYSTEMS MKG.EC.336.

UltraFast imaging architecture offers unique performance in vascular imaging. Detection of transient hemodynamic flows by UltraFast Doppler imaging and displaying of microvasculature with Angio PLUS imaging contribute to the evaluation of global cardiovascular risk.

  • Perform stenosis staging in 3 different locations simultaneously and in a single acquisition during the same cardiac cycle with UltraFast Doppler
  • Conduct ultrasensitive blood flow analysis without compromise with Angio PLUS imaging
  • Improve patient management and monitoring with advanced vascular analysis.

The multiple imaging modalities are a significant advancement in diagnostic tools for prostate cancer assessment, and a first step towards multiparametric ultrasound examination of prostate tissue.

Real-time ShearWave™ Elastography (SWE™ imaging), delivers a quantitative color-coded map of prostate stiffness at the touch of a button. The very large ROI of ShearWave™ Elastography imaging can cover all of the prostate gland allowing for global assessment1 of the prostate stiffness and inhomogeneities and quick localization of suspicious areas.

  • Screen for prostate cancer and characterize lesions.
  • Conduct multiparametric prostate assessments1 and therapy monitoring.
  • Perform targeted prostate biopsies.
  1. Correas J-M, et al. Prostate Cancer: Diagnostic Performance of Real-Time Shear-Wave Elastography. Radiology 2015; 275(1):280-9.

Dedicated optimized presets to meet all imaging needs

Ultrasound is an imaging tool that is particularly well adapted to children because their organs are not very deep. However, conventional pediatric ultrasound exams are sometimes challenging to perform due to small structures that are hard to image, patient movement and/or the inability for young children to perform apnea.

Our ultrasound systems is designed to produce clinically detailed images with excellent spatial resolution for small structures. For children in constant movement, UltraFast Doppler imaging makes vascular exams easier. UltraFast Doppler imaging combines both Color Doppler and Pulsed Wave Doppler

In addition, real-time ShearWave™ Elastography can also be used with children to image tissue elasticity in kilopascals. ShearWave™ Elastography can image liver stiffness even without apnea required and through very small intercostal spaces, or epigastrically, making the pediatric diagnostic.1,2

  • Gain key information (morphology, stiff ness and microvascularization) with real-time multiparametric assessments to enhance diagnostic efficiency and patient monitoring
  • Leverage new ultrasound biomarkers to optimize and guide patient management at an early stage
  • Tailor it to your requirements; a family of pediatric transducers and application-specific presets.
  1. FDA K173021: Additional Indication For Use as an aid to clinical management of patients with liver disease.
  2. Suh CH, et al. Determination of normal hepatic elasticity by using real-time shear-wave elastography. Radiology 2014; 271(3):895- 900.

Non-invasive Imaging Solutions for the Assessment of Breast Lesions With the SuperSonic MACH ultrasound systems, breast specialists now have access to:

Ultrasound is an imaging tool that is particularly well adapted to children because their organs are not very deep. However, conventional pediatric ultrasound exams are sometimes challenging to perform due to small structures that are hard to image, patient movement and/or the inability for young children to perform apnea.

Our ultrasound systems is designed to produce clinically detailed images with excellent spatial resolution for small structures. For children in constant movement, UltraFast Doppler imaging makes vascular exams easier. UltraFast Doppler imaging combines both Color Doppler and Pulsed Wave Doppler

In addition, real-time ShearWave™ Elastography can also be used with children to image tissue elasticity in kilopascals. ShearWave™ Elastography can image liver stiffness even without apnea required and through very small intercostal spaces, or epigastrically, making the pediatric diagnostic.1,2

  • Premium image quality through a comprehensive suite of breast optimized transducers
  • Real-time ShearWave™ Elastography, the most clinically studied shear wave-based elastography technology for breast lesion characterization
  • 3D breast software-based application that offers unique visualizations of breast anatomy and detailed characterization of lesions

It has been demonstrated, by more than 200 peer-reviewed publications1 using ShearWave™ Elastography imaging, that real-time mapping of breast lesion stiffness provides additional diagnostic information to improve the management of patients. ShearWave™ Elastography imaging constitutes a complementary tool for the management of breast cancer patients for:

  • Enhancing breast lesion diagnosis and characterization, including breast 3D assessment 2,3,
  • Improving clinical decision-making for biopsy and treatment,
  • Access prognostic information and therapy monitoring.
  1. PEER-REVIEWED ARTICLES SHEARWAVE™ ELASTOGRAPHY FOR BREAST IMAGING MKG.EC.335.
  2. Berg WA, et al. Shear wave elastography improves the specificity of breast US: the BE1 multinational study of 939 masses. Radiology 2012; 262(2):435 49.
  3. Chen YL, et al. 3 Dimensional shear wave elastography of breast lesions: Added value of color patterns with emphasis on crater sign of coronal plane. Medicine (Baltimore) 2016; 95(39):e4877. doi: 10.1097/MD.0000000000004877

Designed with a focus on diagnostic imaging to:

  • Detect and characterize gynaecological pathologies
  • Choose a comprehensive foetal imaging and reporting solution
  • Add real-time elasticity mapping and ShearWave™ Elastography imaging stiffness measurements as additional diagnostic information in gynaecology to define the most appropriate patient management
  1. Engineering Clinical Evaluation (Ece) V10 Endocavity Probes Evaluation in Gynecology Dr Shojai Aix En Provence; PM.TP/TR.034.
  2. V10 CMR Validation – Institut de Radiologie de Paris – Gynecology; PM.TP/TR.036.

Meeting the needs of liver experts focused on patients with chronic and focal liver disease; allows the user to follow patients throughout the continuum of care.

Non-invasive Management of Liver Disease Throughout the Care Cycle

We offer a suite of diagnostic imaging tools for non-invasive assessment and follow-up of liver diseases. Using a single equipment, morphological, hemodynamic, elasticity and perfusion analysis are now possible.

Excellent B-mode image quality with penetration up to 45 cm

Innovations on the way to becoming essential biomarkers: ShearWave™ PLUS Elastography, UltraFast Doppler imaging, Angio PLUS imaging, Att PLUS, SSp PLUS and Vi PLUS

Advanced features to facilitate results analysis and exchange of data between medical departments: customizable reports, recommended threshold values, connectivity options.

The utility of ShearWave™ Elastography imaging in the management of patients with chronic liver disease has been demonstrated in more than 200 publications1 for:

  • Evaluation2 and diagnosis3 of hepatic fibrosis
  • Quickly and reliably assess liver fibrosis and liver steatosis
  • Non-invasively follow-up and monitor patients over time
  • Screen and characterize focal liver lesion
  1. PEER-REVIEWED ARTICLES SHEARWAVE™ELASTOGRAPHY FOR LIVER AND ABDOMINAL IMAGING MKG.EC.337.
  2. Gao Y, et al. Liver Fibrosis with Two-dimensional US Shear-Wave Elastography in Participants with Chronic Hepatitis B: A Prospective Multicenter Study. Radiology 2018; 289(2):407-15.
  3. Garcovich M, et al. Liver Stiffness in Pediatric Patients with Fatty Liver Disease: Diagnostic Accuracy and Reproducibility of Shear-Wave Elastography. Radiology 2017; 283(3):820-7.

Deliver accurate exam information critical to your thyroid diagnostic challenges.

TissueTuner eases your workflow by optimizing resolution to achieve the best delineation of structures. Five adjustable settings correct the speed of sound in the tissue being scanned to give you an impeccable image, every time.

Pioneering Thy-RADS tool enables quick identification and documentation for all your nodule characterization needs.

  • Simultaneously assess thyroid morphology, microvascularization and stiffness in real time with TriVu
  • Perform multiparametric nodule characterization and TI-RADS classification
  • Take advantage of ShearWave™ Elastography, which renders a real-time, quantitative (kPa) color-coded assessment, to characterize both thyroid nodules and cervical lymph nodes and guide biopsies